- Sep 08, 2018
-
-
Matthias Kaehlcke authored
The documentation of Qualcomm's SPMI PMIC voltage ADC claims that the 'reg' property consists of two values, the SPMI address and the length of the controller's registers. However the SPMI bus to which it is added specifies "#size-cells = <0>;". Remove the controller register length from the documentation of the field and the example. Signed-off-by:
Matthias Kaehlcke <mka@chromium.org> Reviewed-by:
Douglas Anderson <dianders@chromium.org> Reviewed-by:
Rob Herring <robh@kernel.org> Signed-off-by:
Jonathan Cameron <Jonathan.Cameron@huawei.com>
-
- Aug 03, 2018
-
-
Siddartha Mohanadoss authored
PMIC5 ADC has support for clients to measure voltage and current on inputs connected to the PMIC. Clients include reading voltage phone power and on board system thermistors for thermal management. ADC5 on certain PMIC has support to read battery current. This change adds documentation. Signed-off-by:
Siddartha Mohanadoss <smohanad@codeaurora.org> Reviewed-by:
Rob Herring <robh@kernel.org> Signed-off-by:
Jonathan Cameron <Jonathan.Cameron@huawei.com>
-
- Jan 28, 2015
-
-
Stanimir Varbanov authored
Document DT binding for Qualcomm SPMI PMIC voltage ADC driver. Signed-off-by:
Stanimir Varbanov <svarbanov@mm-sol.com> Signed-off-by:
Ivan T. Ivanov <iivanov@mm-sol.com> Signed-off-by:
Jonathan Cameron <jic23@kernel.org>
-